Need storm damage electrical repair in Tampa Bay? Keywest Lights & Electric repairs electrical damage from hurricanes, tropical storms, lightning and flooding across Pinellas, Hillsborough and Pasco counties. We are a woman-owned contractor under license EC13014717, and we make the system safe first, then restore power in stages.
Request storm damage electrical repair in Tampa Bay
Tell us what you need and where the work is. A licensed electrician will reply with next steps and a time to visit.
Call or text (727) 476-7079 · open 24/7 for emergencies · request a quote online

Storm damage electrical repair in Tampa Bay: safety first
After a storm, electrical hazards hide in plain sight. Water inside a panel, a flooded outlet, a tree on a service line and a surge-damaged appliance are all risks. Do not touch downed wires. Do not walk through standing water near electrical equipment. Call the power company for the line and call us for the rest.
Types of storm damage
- Flooded panels and outlets: water in boxes and conduit.
- Surge damage: burned appliances, boards and electronics.
- Lightning strikes: damaged wiring, outlets and devices.
- Wind damage: pulled masts, meters and fixtures.
- Tree damage: cut cables and broken conduit.
- Roof leaks: water in attic wiring and lights.
- Generator problems: backfeed and bad connections.
What we do first
- Florida electrical contractor license EC13014717, licensed & insured
- Woman-owned business based at 6248 Seminole Blvd, Seminole FL 33772
- 2-year workmanship warranty, 5 years with a Member Care Plan
- SPAN Authorized Installer and Home Depot preferred contractor
- Open 24/7 for electrical emergencies: call or text (727) 476-7079
We make the area safe. If water reached the panel or outlets, we keep the power off, document the damage and test for hazards. If the service is damaged, we coordinate with the power company. Once it is safe, we dry, test and repair in stages, restoring power circuit by circuit.
Flood-damaged equipment
Electrical parts that have been submerged are usually replaced, not dried. Panels, breakers, outlets, switches and wiring devices may be corroded inside. Water that carries salt or sewage is worse. We replace damaged devices, test the wire and clean the area. If a panel is soaked, we replace it.
Surge and lightning damage
Lightning can burn a circuit board in an appliance without visible damage to the outlet. Dead outlets, a dead air conditioner or flickering lights may signal damage. We test, replace damaged devices and add whole-house surge protection to guard against the next strike.
Insurance documentation
Photos, notes and written reports help claims. We document the damage, the cause and the repair, and we write a summary you can send to your insurer. Keep receipts and do not discard damaged parts until the adjuster has seen them.
Generators and safe backup
Generators help in outages but must be used safely. Never plug a generator into a household outlet, and never run one indoors. An interlock or transfer switch is the safe connection. We install them and check generators for proper grounding.
Preparing before the next storm
Surge protection, a generator inlet, a labeled panel, raised outlets in flood areas and a checklist all reduce risk. A Member Care Plan includes a pre-season check. Call us in spring, before storm season gets busy.
Quotes, permits and warranty
Storm repairs often need permits and inspections, which we handle. Our workmanship carries a 2-year warranty, or 5 years with a Member Care Plan.
Salt water and why it matters
Salt water is far more corrosive than fresh water, and it leaves conductive residue. Even after the water is gone, salt in outlets and panels can cause arcing. We replace salt-soaked devices instead of cleaning them. Coastal storm surge is a particular risk in Pinellas communities near the bay.
Attic and roof leak damage
Water dripping through ceilings finds wiring, junction boxes and recessed lights. We check for wet insulation, rusted boxes and corroded splices. Light fixtures filled with water should be removed. Do not use switches in a room with a wet ceiling until it is inspected.
Staged power restoration
After major damage, we restore power in steps: first the circuits we have tested, then others as they are repaired. This keeps refrigerators and air conditioning running while we continue. We label dead circuits so no one uses them by mistake.
Appliances, electronics and surge damage
Appliances with circuit boards, such as air conditioners, refrigerators and TVs, may fail after surges. We test the supply to the appliance and tell you whether the outlet or the appliance is at fault. Appliance repair is a separate trade, and we help you decide which to call.
Commercial storm response
Businesses lose income when power stays down. We prioritize panels, refrigeration and critical circuits, help with temporary power and document damage for insurers. We coordinate with building managers and contractors to reopen safely.
Safety checklist after a storm
Stay out of flooded rooms with plugged-in devices. Turn off the main only if you can reach it while dry. Do not touch wet appliances. Keep children and pets away from damaged wires and boxes. Use flashlights instead of candles. Write down what you see and take photographs from a safe distance.
Drying, testing and meggering
Wet wiring may look fine but fail later. We dry out boxes, then test insulation resistance with a meter that applies higher voltage than a normal tester. Readings below spec mean replacement. This avoids hidden faults that cause fires months later.
Working with adjusters
Insurance adjusters need clear descriptions, photographs and itemized lists. We write a plain report of what failed, what we replaced and why. It helps your claim move faster and keeps repair scope clear.
Smoke odor and scorch marks
A sharp smell near an outlet, brown marks on a faceplate or a warm switch point to arcing inside the wall. We open the box, trace the cause and replace damaged cable back to sound wire. Do not reset a tripping breaker repeatedly.
Common questions
Is it safe to turn the power back on after flooding? Not until a licensed electrician has inspected the system. Water inside panels and outlets is dangerous.
Can flooded outlets be dried and reused? Usually they must be replaced, since corrosion hides inside.
What should I do about a downed power line? Stay far away and call the power company and emergency services.
Will surge protection prevent all damage? It reduces risk but cannot stop a direct strike. It helps protect electronics.
Do you help with insurance claims? We provide photos and written reports of the damage and repairs.
Can I use a generator after the storm? Yes, with a safe connection. Never backfeed through an outlet.
How soon can you start? We prioritize safety hazards and outages, and schedule as quickly as we can.
Do you repair commercial storm damage? Yes. We serve homes and businesses.
Local pages: storm damage electrical repair in Seminole, our home base. See also Pinellas County, Hillsborough County and Pasco County service areas, or browse all electrical services. Also available here: storm damage electrical repair.
Call or text (727) 476-7079 for storm damage electrical repair in Tampa Bay, or book online. Business hours 7 AM–5 PM, weekend service, 24/7 emergency calls.