Need meter base replacement in South Highpoint? When the socket that holds the meter is burned, cracked or no longer accepted, that job is meter base replacement in South Highpoint with Keywest Lights & Electric. Our Seminole Blvd shop is a short drive of about 7 miles. The company is licensed and woman-owned. The same crew also covers emergency electrician in South Highpoint.
Request meter base replacement in South Highpoint
Tell us what you need and where the work is. A licensed electrician will reply with next steps and a time to visit.
The same South Highpoint crew also handles a commercial electrician, a commercial standby generator, EV charger hookups, backup generator hookups, generator interlock and transfer switch work, permanent Christmas lights, panel upgrade or replacement, permanent lighting along the eaves and a 240-volt outlet.
Call or text (727) 476-7079 · open 24/7 for emergencies · request a quote online

Meter base replacement in South Highpoint is the socket itself, not a mast cap or a main breaker
This page is the meter can: the jaws, the hub, the ring or the ringless cover, and the lugs that land the service conductors. Weatherhead work, a main-breaker swap and a full service change have their own pages. We keep this visit on the socket.
A burned jaw on a mid-1970s can
Many houses here date to around 1974, and a lot of the original cans are still on the wall. A jaw that has run hot will scar, loosen or melt the surrounding insulation. We open the can, we photograph the damage, and we replace the socket rather than file the jaw and hope it holds.
Ring versus ringless, decided by what the can is listed for
- Florida electrical contractor license EC13014717, licensed & insured
- Woman-owned business based at 6248 Seminole Blvd, Seminole FL 33772
- 2-year workmanship warranty, 5 years with a Member Care Plan
- SPAN Authorized Installer and Home Depot preferred contractor
- Open 24/7 for electrical emergencies: call or text (727) 476-7079
A ring-type can and a ringless can are not interchangeable covers on the same body. We match the style the power company will actually reseal. We do not leave a ringless cover on a ring-type body, or the other way around, just because the cover was in the truck.
A glass that no longer seats
If the meter will not sit flush, the ring will not close or the cover rocks on the gasket, the socket is the problem, not a “tightened” glass. We replace the can so the meter can seat and the seal path can close honestly.
A two-family can the owner has to release
About half the homes here are rented, and many lots are duplexes or small 3-to-4-unit buildings. A tenant can report a burned socket. The owner or the office has to approve the outage and the new can. We work the can that was hired, and we will not open a neighbor’s sealed socket from a tenant request alone.
A manufactured-home pedestal socket that is not a house-wall can
About a quarter of the homes here are manufactured. The meter may sit in a pedestal, not on a block wall. We bring a listed pedestal socket or a listed replacement can for that pedestal. A house-wall can forced onto a pedestal post is not a swap we will complete.
Work this visit will not take on
We do not climb a mast on this ticket unless the hub or the nipple at the can is part of the socket swap. We do not pull a main inside the house panel as a substitute for a failed socket. We do not invent a review, a price or a job we did not do.
A socket card we leave in the job file
After the new can is landed and the meter can reseat, we leave a socket card. It notes the can type, the jaw count, the hub size and the outage window. Keep it with the house papers or with the rental file.
Forms when the socket and the service path change
A like-for-like socket on the same service can be a short, coordinated outage. A new hub, a different can size or a change in the service path usually needs forms. We file what the job requires, and we stay when an inspection is set. A mail label that says Largo still leaves the lot under unincorporated Pinellas rules.
How long our workmanship holds on a new socket
The socket, the lugs and the enclosure we install carry two years of workmanship coverage. If the house is on the Member Care Plan at /member-care-plans/, that coverage lasts five years. The meter itself, when it belongs to the power company, stays outside that coverage.
A frozen bypass lever we will not force
Some cans have a lever bypass. A frozen lever is not a hammer job. Forcing it can wreck the jaws and the meter. We replace the can with a listed bypass type the site actually uses, or we say plainly if that style is not the right path.
A plastic can that has warped in the sun
A plastic enclosure can bow, fade and lose the cover fit on a west wall. We do not shim a warped cover and call the socket sound. We put up a listed can that still closes and still holds a seal.
Pigtails too short to land in the new lugs
A mid-1970s nipple often leaves very little spare conductor. If the existing tails cannot land with a proper bend in the new lugs, we plan a longer, listed path. We will not pinch short aluminum or copper just to close the cover that afternoon.
A rusted nipple at the can, not at the mast
The short nipple into the hub rusts from splash and from a failed gasket. That failure belongs on this page because it is part of the can. A cracked cap thirty feet up the mast is a weatherhead visit, and we will say so if that is what we find.
Flood splash on a short lot along 34th Street North
Lots here are small and inland, with almost no water and no dock to invent, but splash still hits a low can after a heavy rain. We raise or replace a rusted low can when the wall can take a listed height. We do not leave a can sitting in a splash pocket because the old lags were already there.
A horn bypass the new can has to match
If the existing socket uses a horn bypass, the new can has to accept the same method or a listed successor the power company will reseal. We do not swap in a random can and hope the horns still fit.
A cracked hub at the top of the enclosure
A cracked hub leaks into the jaws. Painting the crack or wrapping it with tape is not a repair we will leave. The can comes off, and a listed hub and nipple go in with the new socket.
Aluminum service conductors we will land with the listed method
Older services here often land aluminum in the socket lugs. We use the listed antioxidant and torque, and we do not treat aluminum as if it were copper. If a lug is not listed for the conductor we find, we change the lug or the can, not the story.
A seal path we will not invent or break for convenience
The can has to close so the meter can be resealed. We do not drill a new hole in the cover or leave the ring hanging so someone can return later. If the new can cannot seal, it is not done.
A meter ring that will not close after the swap
A ring that springs open, a missing slot or a cover that will not take the ring means the can or the ring is wrong. We correct the parts. We do not leave a zip-tie on a meter ring and call the socket complete.
A knockout left open beside the new socket
An open knockout is a path for weather and for insects into the jaws. We close every unused opening with a listed plug. A can with a daylight hole beside the meter is not a finished swap.
A can mounted over a hose bib
A hose bib that sprays the can, or a can that blocks the only shutoff, is a poor mount. We shift the new can to a sound, listed location on the same wall when the service path allows it. We will not hide a new socket behind a dripping faucet.
A leaning can we will not leave on failed lag screws
Soft block, rusted lags and a can that leans off the wall will only get worse after the next outage. We remount with a sound backing and listed hardware. A new socket on a failing wall attachment is not a repair we will sign.
A 100-amp leftover can on a larger service we will not hide
The new can has to be listed for the service that actually feeds it. We will not put a smaller leftover can on a larger service and close the cover. If the service size and the can do not match, we stop and we explain the next step.
Headlamps on Ulmerton and a can we will not leave unsecured overnight
If the outage window runs late along the Ulmerton corridor, we still leave the can closed, the meter seated and the area safe. An open socket left for morning is not a stopping point we will use.
A rusty ground lug at the socket we will replace, not ignore
The grounding connection at the can has to land on a sound lug. A rusted, painted-over or missing lug is part of this swap. We replace it. We do not wave at a green wire hanging beside the new can.
Common questions
Can you replace a burned meter socket at a mid-1970s house? Yes, when we can land a listed can, land the conductors with a proper bend and coordinate the outage. If the tails are too short or the service size does not match, we say so first.
Is this the same as weatherhead repair? No. The mast cap, the drip loops and the insulators have their own page. This page is the socket, the jaws and the can on the wall or in the pedestal.
Will you replace a socket on a rented two-family wall? Yes, once the owner or the office approves the outage. We leave the socket card for that file.
Our shop is on Seminole Blvd, about 7 miles from South Highpoint. Crews work near 34th Street North, Roosevelt Boulevard, 49th Street North and Ulmerton Road. We also serve Pinellas Park, Clearwater, St. Petersburg, Feather Sound and Largo.
Up: Meter Base Replacement across Tampa Bay · For everything we do locally, see South Highpoint electrical service.
Cities next door: Bay Pines · Seminole
Call or text (727) 476-7079 for meter base replacement in South Highpoint, or book online. Business hours 7 AM–5 PM, weekend service, 24/7 emergency calls.